6 Rebooting the device
Barix preloads the Instreamer 100 devices with firmware which is current at the day of production.
Barix constantly enhances the capabilities and functions and recommends to keep the firmware on
the Barix Instreamer up-to-date.
Barix recommends the use of the “Serial Rescue” method to update the firmware.
For the alternative method “Web Update” the
“Web server port” has to be set to “0” or “80” to work properly (0 will set the default port “80”).
If the web update is interrupted during the process (power or network loss) the device might
become unreachable. In that case the “Serial Rescue” procedure is the only remedy. Please keep
that in mind when planning a remote update.
6.1 Downloading the latest firmware
To download the latest “Instreamer” firmware version please visit www.barix.com.
In the menu on the left side click on “downloads”
In the center column select select the appropriate device (Instreamer or Instreamer 100) and
click on the name of the device.
Click in the section “Firmware” on the “Instreamer Update Kit” link to download it.
Save the ZIP file and unpack it to a local drive.
Read the "_readme1st.txt" file for detailed instructions.
6.2 Serial Rescue
The “Serial Rescue” procedure loads the entire firmware and resets the device to factory default
settings (current configuration is overwritten).
It is therefore helpful to note the current setting. Printing out the “status” page is the quickest way
as the page contains all configuration parameters.
Open your web browser and type in the IP address of the Barix device in the URL field followed by
“/status” and hit the “Enter” key.
Example: “192.168.0.12/status”
To apply the Rescue using a serial cross cable and a PC running Windows 2000, Windows XP,
Linux or a MAC follow the steps in the “_readme1st.txt” carefully as there are several different
applications (batch files) to be started depending on the Barix hardware (new or legacy) and the
PCs COM port number used.
Calculate approximately 2 minutes to complete the
“Serial Rescue” procedure. After a successful rescue the device is ready for configuration
according to your needs (see chapter 3 Device Configuration).
29 Rebooting the device