Trap Repeat
Define the SNMP trap repeat interval. The trap is repeated if the audio level values are still out of
range.
Silence Timeout
Define the time interval for sending a trap after the low audio level is detected.
3.4 I/O Settings
Configure which of the commands below should be issued when the CTS signal on the serial
connector is activated
CTS close command
Configures which command should be issued when the CTS signal on the serial connector is
activated
CTS open command
Configures which command should be issued when the CTS signal on the serial connector is
deactivated
Commands
Commands can be joined using the “&” character and will be executed sequentially. For further
commands refer to the “Instreamer technical documentation”.
SENDING MODE
c=84 : Deactivate the sending mode, if not send always
c=91 : Activate the sending mode
SERIAL
c=89 : Simulate the CTS Signal being activated
c=90 : Simulate the CTS Signal being deactivated
c=60 : Activate the RTS Signal
c=61 : Deactivate the RTS Signal
21 Device Configuration