User Manual “Instreamer“ - V4.03 - 24th October 2013
SERIAL GATEWAY
The Serial Gateway function allows the
establishment of a serial connection between two
devices over a LAN or WAN.
To enable the Gateway function "Destination IP" and
"Destination port" are set at the initiator (active)
device. At the receiver (passive) device the “Local
port” is set to the partner's “Destination port”.
On power up the active device connects to the
passive device and tries to reconnect automatically
if the connection is lost. If the connection is
successful serial data can be passed end-to-end
across the network.
Local port
Defines the port on which the serial interface can be
accessed for serial gateway applications. Only when
"Local port" is set to
"0"
can the serial interface be
used as a command interface.
If Destination IP is nonzero and the "Local port" is
set to a value then this will be the source port of the
TCP connection. If the Destination IP is nonzero and
"Local port" is
"0"
a random source port is used.
Default:
"12303".
Destination IP
To have this Barix Instreamer actively establish a
serial gateway select the destination IP address of
the device with which serial data will be exchanged.
Select
"0.0.0.0"
to disable the gateway and use the
serial interface locally only.
Default:
"0.0.0.0"
(disabled).
Destination port
Defines the port for the active serial gateway
function (see destination IP).
Default:
"0"
(disabled)