BARIX Instreamer Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 63
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
User Manual “Instreamer“ - V4.03 - 24th October 2013
Other configurations are also possible since in
general entry #7 of the Streaming table modifies the
first entry in the m3u and asx files and entry #8
modifies the second file entry.
Limitation: Although eight entries can be configured
only six concurrent radio servers are supported.
Connection type - RTP entry
Set the connection type to “RTP” (Real Time
Protocol) for an RTP destination. The IP “0.0.0.0”
will broadcast (UDP) on the subnet (e.g.
"192.168.0.255") on the port selected under “Port#”
(e.g. 4040), enter an IP for a UDP unicast destination
(e.g. “192.168.0.11).
Connection type - BRTP entry
Set the connection type in the first entry to “BRTP”
(Barix Real Time Protocol) for a BRTP server (up to
32 clients). The IP “0.0.0.0” will act as a BRTP
listener (UDP) waiting for BRTP clients requesting a
stream on the port selected under “Port#” (e.g. 80).
Up to 32 external devices may register and up to 32
RTP streams at 128kbit/s are supported. This
maximum rate is approximately provided by the
MP3 setting: Encoding+Frequency MPEG1/48kHz
and Encoding quality 5.
Connection type - SIP entry
SIP is only available with the first entry.
Set the connection type to “SIP” for an asterisk SIP
server destination. Enter the IP of the SIP server. SIP
works only when either “u-Law 8kHz” or “a-Law
8kHz” encoding is selected. Enter the UDP port of
the SIP server under “Port#” (Port 0=5060).
See also section icy-url / SIP user further above.
38 /63 BARIX AG | 28. Jan. 2014 | Device Configuration
Vista de pagina 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 62 63

Comentarios a estos manuales

Sin comentarios