9 Remote Configuration and Update interface
Please note that the Remote Firmware Update is supported only on devices with
2MB Flash memory.
Remote Configuration Update as well as Remote Command Execution can be
performed on devices with 1MB as well as 2MB Flash memory.
9.1 Configuration parameters
Update URL
For remote configuration and update the configuration field “Update URL” can be
used to point to the web server (http) containing the “Configuration Meta File”. Only
the HTTP protocol is supported, including all its options and the possibility of using
HTTP Proxy.
Remote Update Period
The URL provided is checked and processed periodically. The frequency of checking
the configuration meta file can be set in the configuration field “Remote Update
Period” in minutes.
9.2 Configuration Meta File
When the “Configuration Meta File” is loaded, it's version of is checked against the
“Remote Update File Version” stored in the EEPROM.
The “Configuration Meta File” is only parsed (executed) if the version is higher.
The “Configuration Meta File” can contain three different types of assignments:
keywords, control commands and config values.
NOTE: Please note that the configuration meta file is case sensitive.
Keywords
ID Type Description
VERSION 16bit unsigned
decimal number
Meta file version
FW_VERSION 16bit unsigned
hexadecimal
number
Version of the firmware file
FW_URL URL string with
maximum length of
99 characters
URL of the firmware .bin file
Control Commands
Control commands are described in chapter WEB .
There must be only one command per line, no command concatenation is
supported. Commands are executed in the same order as they appear in the file.
Config values
Config values are textual descriptors of places in the configuration memory. Config
value names are looked up in the update.ini file (described in the next section, see
chapter 4.1 User Interface Development Kit on how to upload this file).
Execution procedure
Once the version is checked to be higher the “Configuration Meta File” is processed
BARIX AG | 48/63