Technical Documentation “Instreamer “ - V4.03 - 24th October 2013
Element Description CGI command SERIAL, TCP or UDP command
kilobytes per second.
ex. for MPEG2/24khz VBR and encoding quality 6:
hexadecimal 0x602 is decimal 1538. The command then will
be e=1538
e=255 restarts the encoder without changing the settings.
SETSERGATEWAY Sets the destination IP address and port for the serial
gateway and connect to it. Alternatively, close an existing
connection by setting a zero IP address. If this command is
executed via the serial command interface the connection will
be closed 1 sec after the last transmitted or received byte.
g=[<ip>][:<port>]
<ip> is the destination IP address. 0.0.0.0 to close the
connection.
<port> is the destination port. If none, LOCALPORT is used.
g=… 0x67 0x3D … 0x00 (g=… )
SENDIR Transmit an IR command.
This command is word organized (2 bytes, high byte first).
The words can be separated by a comma (no spaces). The
word is interpreted as a hexadecimal value.
The first word is the selection for the IR command data
following. It is organized in bits.
Low Byte: 0x01 = SONY IR modulation
0x02 = RC 5 IR modulation
0x04 = NEC IR modulation
0x80 = RAW IR modulation
Bit 8-14: 0 for base band
1 for 37.5 kHz modulation frequency
2 for 60 kHz modulation frequency
Bit 15: 0 for transmit on serial port 0 (Serial IR
Dongle)
1 for transmit on IR OUT
Example: 8102 for RC 5 IR modulation with 37.5 kHz on IR
OUT.
j=… 0x70 0x3D … 0x00 (j=… )
11 Software Application Interface Software Application Interface 11